Temperature: 1000°C / 1832°F

1000 degree Celsius (°C) RESIDUE ANALYSIS FURNACE CHAMBER SIZE 315 × 315 × 585 MM

View in:
4.7 (16 ratings)
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 9748088783
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 9748088783
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 9748088783
Base Price (Excl. GST)
₹72,982.05
+ Packaging: ₹7,706.91 (optional for factory/self pickup)
+ GST (18%): ₹13,136.77
* Shipping calculated at checkout
Est. Total (incl. GST + packaging): ₹93,825.73
units
📫 Enquire
Product Specifications
CategoryMuffle Furnace
ModelResidue Analysis Furnace
Max Temperature1000°C (1832°F)
Working Temperature900°C
Thermocouple TypeN (Nicrosil-Nisil)
Thermocouple DetailsType N, Tolerance Class 2, 0 to +1100°C range, MgO insulated mineral, Inconel 600 sheath, 6mm diameter
Heating ElementKanthal A1 (FeCrAl)
Element DetailsFeCrAl alloy with rare earth elements, Max temp: 1425°C, Superior cyclic performance
Chamber (MM)315 × 315 × 585
Outer Body (MM)715.0 × 915.0 × 860.0
Chamber Volume58 Litres
Volume (cu.ft)21.1 ft³
Power Load14.900 kW
Power Supply440V, Three Phase
Gross Weight173 kg
Chamber ShapeSquare
Customise Your Order
Body Material
Body Paint Type
Temperature Controller
Safety Device

About This 1000°C Residue Analysis Furnace 315 × 315 × 585 MM Chamber

This furnace is used in analytical laboratories to determine the residue content of a material, often by burning off the non-residue portion. Operating at temperatures like 600°C, it facilitates controlled combustion. The working principle involves igniting a weighed sample and heating it until only inorganic ash remains, which is then weighed. Its purpose is to measure the inorganic (mineral) content of fuels, foodstuffs, polymers, and lubricants, providing important quality and compliance data for industries like petroleum, food processing, and plastics manufacturing.

Trutherm manufactures 1000 Degree Celsius (1000°C) Residue Analysis Furnace 315 × 315 × 585 MM Chamber for buyers who search by exact machine type, chamber size and 1000°C temperature rating. This page is specific to the MM dimension version, so the chamber size is presented in the unit normally used in the buyer's drawing, tender or purchase request.

This configuration is suitable when the sample load must fit a 315 × 315 × 585 MM chamber with usable chamber volume of 58 litre, approximate power load of 14.900 kW, square chamber profile. It is commonly selected for laboratory, QC, metallurgical, ceramic, pharmaceutical and industrial heat-treatment work requiring stable heating and repeatable process conditions.

Equivalent chamber references: 315 × 315 × 585 MM, 32 × 32 × 59 CM and 12 × 12 × 23 INCH. Buyers searching for 1000 Degree Celsius Residue Analysis Furnace 315 × 315 × 585 MM chamber; 1000°C Residue Analysis Furnace 315 × 315 × 585 MM; 1000 Degree Celsius Residue Analysis Furnace 32 × 32 × 59 CM chamber; 1000°C Residue Analysis Furnace 32 × 32 × 59 CM; 1000 Degree Celsius Residue Analysis Furnace 12 × 12 × 23 INCH chamber; 1000°C Residue Analysis Furnace 12 × 12 × 23 INCH can verify the same physical chamber on this canonical product page before requesting price, GST invoice, packaging and delivery.

FAQs for 1000 Degree Celsius (1000°C) Residue Analysis Furnace 315 × 315 × 585 MM Chamber

What is 1000 Degree Celsius (1000°C) Residue Analysis Furnace 315 × 315 × 585 MM Chamber best suited for? It is best suited for controlled heating jobs where this exact 315 × 315 × 585 MM chamber size must fit the sample, crucible, tray or batch volume.
Can Trutherm supply 1000 Degree Celsius (1000°C) Residue Analysis Furnace 315 × 315 × 585 MM Chamber with custom controls? Yes. Controller type, safety devices, body material, power connection and documentation can be configured according to application and site requirements.
Is this chamber size available in CM and INCH also? Yes. The same chamber is listed as 315 × 315 × 585 MM, 32 × 32 × 59 CM and 12 × 12 × 23 INCH so searches and purchase documents using any common dimension unit match this product.
How is pricing decided for 1000 Degree Celsius (1000°C) Residue Analysis Furnace 315 × 315 × 585 MM Chamber? Price depends on chamber size, temperature rating, insulation, heating element, controller, electrical load, packaging, GST and delivery requirements.

Related Furnace Pages

Residue Analysis Furnace manufacturer 1000 Degree Celsius Residue Analysis Furnace chamber sizes Residue Analysis Furnace 315 × 585 × 315 MM chamber Residue Analysis Furnace 585 × 315 × 315 MM chamber Residue Analysis Furnace 615 × 310 × 310 MM chamber Residue Analysis Furnace 310 × 615 × 310 MM chamber
Product Enquiry
Verify: 6 + 2 = ?

Products You May Be Interested In

Refractory Testing Furnace
Muffle Furnace
Refractory Testing Furnace
Glazing Furnace
Muffle Furnace
Glazing Furnace
Digital Precious Metal Furnace
Muffle Furnace
Digital Precious Metal Furnace
Hot Press Furnace
Muffle Furnace
Hot Press Furnace
Drying Furnace
Muffle Furnace
Drying Furnace
Stoneware Furnace
Muffle Furnace
Stoneware Furnace