Web Analytics Made Easy - Statcounter
 +91 8100640898 (11 AM to 6 PM)    +91 9475747057
1000°C Residue Analysis Furnace Chamber 350 x 350 x 600 MM / 35 x 35 x 60 CM / 14 x 14 x 24 INCH | Manufacturer India
This is a sample image
actual model may differ
Direct Manufacturer GST Invoice Pan-India Delivery
Temperature: 1000°C / 1832°F

1000 degree Celsius (°C) RESIDUE ANALYSIS FURNACE CHAMBER SIZE 350 x 350 x 600 MM

View in:
4.9 (18 ratings)
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
Base Price (Excl. GST)
₹81,813.49
+ Packaging: ₹8,523.22 (optional for factory/self pickup)
+ GST (18%): ₹14,726.43
* Shipping calculated at checkout
Est. Total (incl. GST + packaging): ₹105,063.14
units
Product Specifications
CategoryMuffle Furnace
ModelResidue Analysis Furnace
Max Temperature1000°C (1832°F)
Working Temperature900°C
Thermocouple TypeN (Nicrosil-Nisil)
Thermocouple Details0 to +1100°C range, MgO insulated mineral, Inconel 600 sheath, 6mm diameter, Type N, Tolerance Class 2
Heating ElementKanthal A1 (FeCrAl)
Element DetailsSuperior cyclic performance, FeCrAl alloy with rare earth elements, Max temp: 1425°C
Chamber (MM)350 x 350 x 600
Outer Body (MM)753.0 x 954.0 x 874.0
Chamber Volume73.5 Litres
Volume (cu.ft)23.1 ft³
Power Load15.91 kW
Power Supply440V, Three Phase
Gross Weight199.75 kg
Chamber ShapeSquare
Customise Your Order
Body Material
Body Paint Type
Temperature Controller
Safety Device

About This 1000°C Residue Analysis Furnace 350 x 350 x 600 MM Chamber

This furnace is used in analytical laboratories to determine the residue content of a material, often by burning off the non-residue portion. Operating at temperatures like 600°C, it facilitates controlled combustion. The working principle involves igniting a weighed sample and heating it until only inorganic ash remains, which is then weighed. Its purpose is to measure the inorganic (mineral) content of fuels, foodstuffs, polymers, and lubricants, providing important quality and compliance data for industries like petroleum, food processing, and plastics manufacturing.

Equivalent chamber references: 350 x 350 x 600 MM, 35 x 35 x 60 CM and 14 x 14 x 24 INCH. Buyers searching for 1000 Degree Celsius Residue Analysis Furnace 350 x 350 x 600 MM chamber; 1000°C Residue Analysis Furnace 350 x 350 x 600 MM; 1000 Degree Celsius Residue Analysis Furnace 35 x 35 x 60 CM chamber; 1000°C Residue Analysis Furnace 35 x 35 x 60 CM; 1000 Degree Celsius Residue Analysis Furnace 14 x 14 x 24 INCH chamber; 1000°C Residue Analysis Furnace 14 x 14 x 24 INCH can verify the same physical chamber on this canonical product page before requesting price, GST invoice, packaging and delivery.

Trutherm manufactures 1000 Degree Celsius (1000°C) Residue Analysis Furnace 350 x 350 x 600 MM Chamber for buyers who search by exact machine type, chamber size and 1000°C temperature rating. This page is specific to the MM dimension version, so the chamber size is presented in the unit normally used in the buyer's drawing, tender or purchase request.

This configuration is suitable when the sample load must fit a 350 x 350 x 600 MM chamber with usable chamber volume of 73.5 litre, approximate power load of 16.4 kW, square chamber profile. It is commonly selected for laboratory, QC, metallurgical, ceramic, pharmaceutical and industrial heat-treatment work requiring stable heating and repeatable process conditions. Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.

Uniform chamber heating and a simple door-loading design make a muffle furnace straightforward to standardise across multiple operators and shifts.

Where sample volume and process type vary week to week, a general-purpose muffle furnace avoids the cost of maintaining several process-specific furnace types.

FAQs for 1000 Degree Celsius (1000°C) Residue Analysis Furnace 350 x 350 x 600 MM Chamber

Is this chamber size available in CM and INCH also? Yes. The same chamber is listed as 350 x 350 x 600 MM, 35 x 35 x 60 CM and 14 x 14 x 24 INCH so searches and purchase documents using any common dimension unit match this product.
How is pricing decided for 1000 Degree Celsius (1000°C) Residue Analysis Furnace 350 x 350 x 600 MM Chamber? Price depends on chamber size, temperature rating, insulation, heating element, controller, electrical load, packaging, GST and delivery requirements.
What is Residue Analysis Furnace typically used for? Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.
What is 1000 Degree Celsius (1000°C) Residue Analysis Furnace 350 x 350 x 600 MM Chamber best suited for? It is best suited for controlled heating jobs where this exact 350 x 350 x 600 MM chamber size must fit the sample, crucible, tray or batch volume.
Can Trutherm supply 1000 Degree Celsius (1000°C) Residue Analysis Furnace 350 x 350 x 600 MM Chamber with custom controls? Yes. Controller type, safety devices, body material, power connection and documentation can be configured according to application and site requirements.

Application Examples

  • General laboratory heat treatment, drying and ashing across sample types.
  • Calcination and loss-on-ignition testing.
  • Small-batch annealing and stress-relieving of metal parts.
  • Teaching and demonstration use in institutional labs.

Industry Use-Cases

  • Multi-purpose QC and testing laboratories.
  • Educational institutions running heat-treatment demonstrations.
  • Small manufacturers needing an all-round furnace.
  • Research groups with varied, low-volume heating needs.

Recommended Accessories

Ceramic sample trays Spare K-type thermocouple Heat-resistant handling gloves PID controller upgrade

Why Choose This Residue Analysis Furnace

As a general-purpose muffle furnace, this model covers a broader range of routine heating tasks than a process-specific ashing, tube or sintering furnace, making it the practical default when the lab runs mixed sample types rather than one dedicated process.

Related Furnace Pages

1000 Degree Celsius Residue Analysis Furnace chamber sizes Residue Analysis Furnace 330 x 660 x 330 MM chamber Residue Analysis Furnace 660 x 330 x 330 MM chamber Residue Analysis Furnace 350 x 600 x 350 MM chamber Residue Analysis Furnace 600 x 350 x 350 MM chamber Residue Analysis Furnace manufacturer

Products You May Be Interested In

Metal Hardening Furnace
Muffle Furnace
Metal Hardening Furnace
Brass Furnace
Muffle Furnace
Brass Furnace
Bead Kiln
Muffle Furnace
Bead Kiln
Lab Muffle Furnace
Muffle Furnace
Lab Muffle Furnace
Dental Ceramic Sintering Furnace
Muffle Furnace
Dental Ceramic Sintering Furnace
Copper Alloy Furnace
Muffle Furnace
Copper Alloy Furnace