| Category | Muffle Furnace |
| Model | Burn Out Furnace |
| Max Temperature | 1200°C (2192°F) |
| Working Temperature | 1100°C |
| Thermocouple Type | S (Platinum-10% Rhodium) |
| Thermocouple Details | Type S, Tolerance Class 2, 0 to +1450°C range, High purity alumina insulation, Platinum sheath, 6mm diameter |
| Heating Element | Kanthal A1 (FeCrAl) |
| Element Details | FeCrAl alloy with rare earth elements, Max temp: 1425°C, Superior cyclic performance |
| Chamber (MM) | 270 x 270 x 510 |
| Outer Body (MM) | 685.0 x 875.0 x 795.0 |
| Chamber Volume | 37.2 Litres |
| Volume (cu.ft) | 17 ft³ |
| Power Load | 12.04 kW |
| Power Supply | 440V, Three Phase |
| Gross Weight | 137.18 kg |
| Chamber Shape | Square |
Used primarily in investment casting (lost-wax process), this furnace combusts the wax or plastic patterns from within the ceramic investment mold. Operating around 750°C, it completely eliminates the pattern material. The working principle involves heating the mold slowly to melt, vaporize, and burn out the wax, leaving a clean, precise cavity, while also curing the mold ceramic to develop strength. Its purpose is a critical preparatory step before pouring molten metal, ensuring the final casting's dimensional accuracy and surface finish. It is indispensable in jewelry making, dental labs, and precision casting foundries.
Equivalent chamber references: 270 x 270 x 510 MM, 27 x 27 x 51 CM and 10 x 10 x 20 INCH. Buyers searching for 1200 Degree Celsius Burn Out Furnace 270 x 270 x 510 MM chamber; 1200°C Burn Out Furnace 270 x 270 x 510 MM; 1200 Degree Celsius Burn Out Furnace 27 x 27 x 51 CM chamber; 1200°C Burn Out Furnace 27 x 27 x 51 CM; 1200 Degree Celsius Burn Out Furnace 10 x 10 x 20 INCH chamber; 1200°C Burn Out Furnace 10 x 10 x 20 INCH can verify the same physical chamber on this canonical product page before requesting price, GST invoice, packaging and delivery.
Trutherm manufactures 1200 Degree Celsius (°C) Burn Out Furnace 270 x 270 x 510 MM Chamber for buyers who search by exact machine type, chamber size and 1200°C temperature rating. This page is specific to the MM dimension version, so the chamber size is presented in the unit normally used in the buyer's drawing, tender or purchase request.
This configuration is suitable when the sample load must fit a 270 x 270 x 510 MM chamber with usable chamber volume of 37.2 litre, approximate power load of 12.4 kW, square chamber profile. It is commonly selected for laboratory, QC, metallurgical, ceramic, pharmaceutical and industrial heat-treatment work requiring stable heating and repeatable process conditions. Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.
Routine QC and teaching labs value a muffle furnace precisely because one unit can cover several standard test methods without dedicated process-specific tooling.
Uniform chamber heating and a simple door-loading design make a muffle furnace straightforward to standardise across multiple operators and shifts.
As a general-purpose muffle furnace, this model covers a broader range of routine heating tasks than a process-specific ashing, tube or sintering furnace, making it the practical default when the lab runs mixed sample types rather than one dedicated process.