+91 8100640898 (11 AM to 6 PM)    +91 9475747057
1200°C Sulfur Determination Furnace Chamber 470 × 875 × 470 MM / 47 × 88 × 47 CM / 18 × 35 × 18 INCH | Manufacturer India
This is a sample image
actual model may differ
Direct Manufacturer GST Invoice Pan-India Delivery
Temperature: 1200°C / 2192°F

1200 degree Celsius (°C) SULFUR DETERMINATION FURNACE CHAMBER SIZE 470 × 875 × 470 MM

View in:
5.0 (20 ratings)
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 9748088783
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 9748088783
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 9748088783
Base Price (Excl. GST)
₹146,383.33
+ Packaging: ₹11,448.65 (optional for factory/self pickup)
+ GST (18%): ₹26,349.00
* Shipping calculated at checkout
Est. Total (incl. GST + packaging): ₹184,180.98
units
📫 Enquire
Product Specifications
CategoryMuffle Furnace
ModelSulfur Determination Furnace
Max Temperature1200°C (2192°F)
Working Temperature1100°C
Thermocouple TypeS (Platinum-10% Rhodium)
Thermocouple DetailsType S, Tolerance Class 2, 0 to +1450°C range, High purity alumina insulation, Platinum sheath, 6mm diameter
Heating ElementKanthal A1 (FeCrAl)
Element DetailsFeCrAl alloy with rare earth elements, Max temp: 1425°C, Superior cyclic performance
Chamber (MM)470 × 875 × 470
Outer Body (MM)870.0 × 1475.0 × 745.0
Chamber Volume193.3 Litres
Volume (cu.ft)35.9 ft³
Power Load24.300 kW
Power Supply440V, Three Phase
Gross Weight317 kg
Chamber ShapeRectangular - tall
Customise Your Order
Body Material
Body Paint Type
Temperature Controller
Safety Device

About This 1200°C Sulfur Determination Furnace 470 × 875 × 470 MM Chamber

This analytical furnace is used to determine the sulfur content in materials like coal, oil, and steel. Operating at high temperatures (around 1000°C), it combusts the sample in an oxygen-rich environment. The working principle involves burning the sample, converting all sulfur to sulfur dioxide (SO2), which is then measured by infrared detection or titration. Its purpose is critical for environmental compliance (monitoring fuel sulfur levels), metallurgical quality control (sulfur weakens steel), and in the petrochemical industry for feedstock analysis.

Trutherm manufactures 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 470 × 875 × 470 MM Chamber for buyers who search by exact machine type, chamber size and 1200°C temperature rating. This page is specific to the MM dimension version, so the chamber size is presented in the unit normally used in the buyer's drawing, tender or purchase request.

This configuration is suitable when the sample load must fit a 470 × 875 × 470 MM chamber with usable chamber volume of 193.3 litre, approximate power load of 24.300 kW, rectangular - tall chamber profile. It is commonly selected for laboratory, QC, metallurgical, ceramic, pharmaceutical and industrial heat-treatment work requiring stable heating and repeatable process conditions.

Equivalent chamber references: 470 × 875 × 470 MM, 47 × 88 × 47 CM and 18 × 35 × 18 INCH. Buyers searching for 1200 Degree Celsius Sulfur Determination Furnace 470 × 875 × 470 MM chamber; 1200°C Sulfur Determination Furnace 470 × 875 × 470 MM; 1200 Degree Celsius Sulfur Determination Furnace 47 × 88 × 47 CM chamber; 1200°C Sulfur Determination Furnace 47 × 88 × 47 CM; 1200 Degree Celsius Sulfur Determination Furnace 18 × 35 × 18 INCH chamber; 1200°C Sulfur Determination Furnace 18 × 35 × 18 INCH can verify the same physical chamber on this canonical product page before requesting price, GST invoice, packaging and delivery.

FAQs for 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 470 × 875 × 470 MM Chamber

What is 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 470 × 875 × 470 MM Chamber best suited for? It is best suited for controlled heating jobs where this exact 470 × 875 × 470 MM chamber size must fit the sample, crucible, tray or batch volume.
Can Trutherm supply 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 470 × 875 × 470 MM Chamber with custom controls? Yes. Controller type, safety devices, body material, power connection and documentation can be configured according to application and site requirements.
Is this chamber size available in CM and INCH also? Yes. The same chamber is listed as 470 × 875 × 470 MM, 47 × 88 × 47 CM and 18 × 35 × 18 INCH so searches and purchase documents using any common dimension unit match this product.
How is pricing decided for 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 470 × 875 × 470 MM Chamber? Price depends on chamber size, temperature rating, insulation, heating element, controller, electrical load, packaging, GST and delivery requirements.

Related Furnace Pages

Sulfur Determination Furnace manufacturer 1200 Degree Celsius Sulfur Determination Furnace chamber sizes Sulfur Determination Furnace 465 × 465 × 890 MM chamber Sulfur Determination Furnace 470 × 470 × 875 MM chamber Sulfur Determination Furnace 875 × 470 × 470 MM chamber Sulfur Determination Furnace 470 × 880 × 470 MM chamber
Product Enquiry
Verify: 18 + 8 = ?

Products You May Be Interested In

Porcelain Kiln
Muffle Furnace
Porcelain Kiln
Glass Softening Furnace
Muffle Furnace
Glass Softening Furnace
Clay Pottery Furnace
Muffle Furnace
Clay Pottery Furnace
Dental Ceramic Sintering Furnace
Muffle Furnace
Dental Ceramic Sintering Furnace
High Temperature Muffle Furnace
Muffle Furnace
High Temperature Muffle Furnace
Metallographic Sample Furnace
Muffle Furnace
Metallographic Sample Furnace