Web Analytics Made Easy - Statcounter
+91 8100640898
1300 degree Celsius (°C) Combustion Furnace Chamber 500 x 500 x 900 MM / 50 x 50 x 90 CM / 20 x 20 x 36 INCH | Manufacturer India
This is a sample image
actual model may differ
Direct Manufacturer GST Invoice Pan-India Delivery
📈 Estimated Heating Profile
Illustrative engineering estimate for an empty, well-insulated chamber (Ceramic Fibre Board (HP Grade, 1430°C rated), 125mm) — not a measured guarantee. Actual heat-up time varies with load mass, door-opening frequency, and mains voltage stability.
0°C200°C400°C600°C800°C1000°C1200°C1300°C maximum1200°C continuous rated03673109146182Heating Time (minutes)
Approx. no-load heat-up to 1200°C: 182 minutes.
Indicative Heat-Balance Split (at soak, 1200°C)
Useful heating (process load) — 56%
Wall conduction loss (insulation) — 20%
Door / flange radiation loss — 11%
Chamber ventilation loss — 6%
Safety / control margin — 7%
Indicative Temperature Gradient Across Insulation Layers
0200400600800100012001200°CChamberface766°CDense refractoryboard332°CCeramic fibremodule109°CBackup mineralwool61°COuter MSbodyIndicative Temperature Gradient Across Insulation LayersMulti-layer wall, chamber at 1200°C soak
Based on 25.8 kW installed load and the product-specific chamber/body geometry. The heat-up curve is calibrated to the FIEMF-12H190 technical-datasheet schedule; heat-balance and wall-gradient values remain engineering estimates, not measured guarantees.
Temperature: 1300°C / 2372°F

1300 degree Celsius (°C) COMBUSTION FURNACE CHAMBER SIZE 500 x 500 x 900 MM

View in:
4.9 (18 ratings)
Price Starts From (Basic Model)
₹417,408.75 + GST @ 18%
📫 Send Enquiry 📞 Call Us
Product Specifications
CategoryMuffle Furnace
ModelCombustion Furnace
Max Temperature1300°C (2372°F)
Working Temperature1200°C
Thermocouple TypeS (Platinum-10% Rhodium)
Thermocouple Details8mm diameter, Type S, Tolerance Class 2, 0 to +1550°C range, High purity alumina insulation, Platinum sheath
Heating ElementSilicon Carbide (SiC)
Element DetailsBrittle material, SiC heating elements, Max temp: 1600°C, High power density
Insulation MaterialCeramic Fibre Board (HP Grade, 1430°C rated)
Insulation Thickness125 mm
Chamber (MM)500 x 500 x 900
Outer Body (MM)905.0 x 1105.0 x 1175.0
Chamber Volume225 Litres
Volume (cu.ft)43.1 ft³
Power Load25.8 kW
Power Supply440V, Three Phase
Gross Weight367.24 kg
Chamber ShapeSquare
Body MaterialMS (Mild Steel)
Body Paint TypeLiquid Painting
Temperature ControllerPID On/Off Controller
Safety DeviceMCB

About This 1300°C Combustion Furnace 500 x 500 x 900 MM Chamber

Designed for the complete combustion of materials, this furnace is used for energy generation, waste incineration, or analytical purposes. Operating at temperatures like 800°C, it ensures thorough oxidation. The working principle involves introducing the material into a high-temperature chamber with excess air or oxygen to achieve complete burnout, often with afterburners to eliminate volatile organic compounds. Its purpose in industry is to dispose of hazardous waste or generate heat; in labs, it's used for Loss on Ignition (LOI) or carbon/sulfur determination. It is engineered for safety, efficiency, and compliance with emissions regulations.

Trutherm manufactures 1300 Degree Celsius (°C) Combustion Furnace 500 x 500 x 900 MM Chamber for buyers who search by exact machine type, chamber size and 1300°C temperature rating. This page is specific to the MM dimension version, so the chamber size is presented in the unit normally used in the buyer's drawing, tender or purchase request.

This configuration is suitable when the sample load must fit a 500 x 500 x 900 MM chamber with usable chamber volume of 225 litre, approximate power load of 25.8 kW, square chamber profile. It is commonly selected for laboratory, QC, metallurgical, ceramic, pharmaceutical and industrial heat-treatment work requiring stable heating and repeatable process conditions. Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.

Equivalent chamber references: 500 x 500 x 900 MM, 50 x 50 x 90 CM and 20 x 20 x 36 INCH. Buyers searching for 1300°C Combustion Furnace 500 x 500 x 900 MM; Combustion Furnace 1300°C 500 x 500 x 900 MM; Combustion Furnace 500 x 500 x 900 MM 1300°C; 500 x 500 x 900 MM 1300°C Combustion Furnace; 1300 Degree Combustion Furnace 500 x 500 x 900 MM; Combustion Furnace 1300 Degree 500 x 500 x 900 MM can verify the same physical chamber on this canonical product page before requesting price, GST invoice, packaging and delivery.

A muffle furnace isolates the sample from direct contact with heating elements or combustion gases, giving cleaner, more repeatable results than an open flame or hot-plate process.

Because muffle furnaces are used across ashing, drying, calcination and light heat-treatment, the chamber and controller are specified for flexibility rather than one narrow process window.

FAQs for 1300 Degree Celsius (°C) Combustion Furnace 500 x 500 x 900 MM Chamber

What is 1300 Degree Celsius (°C) Combustion Furnace 500 x 500 x 900 MM Chamber best suited for? It is best suited for controlled heating jobs where this exact 500 x 500 x 900 MM chamber size must fit the sample, crucible, tray or batch volume.
Can Trutherm supply 1300 Degree Celsius (°C) Combustion Furnace 500 x 500 x 900 MM Chamber with custom controls? Yes. Controller type, safety devices, body material, power connection and documentation can be configured according to application and site requirements.

Application Examples

  • General laboratory heat treatment, drying and ashing across sample types.
  • Calcination and loss-on-ignition testing.
  • Small-batch annealing and stress-relieving of metal parts.
  • Teaching and demonstration use in institutional labs.

Industry Use-Cases

  • Multi-purpose QC and testing laboratories.
  • Educational institutions running heat-treatment demonstrations.
  • Small manufacturers needing an all-round furnace.
  • Research groups with varied, low-volume heating needs.

Recommended Accessories

Ceramic sample trays Spare K-type thermocouple Heat-resistant handling gloves PID controller upgrade

Related Furnace Pages

1300 Degree Celsius Combustion Furnace chamber sizes Combustion Furnace 510 x 860 x 510 MM chamber Combustion Furnace 860 x 510 x 510 MM chamber Combustion Furnace 500 x 900 x 500 MM chamber Combustion Furnace 900 x 500 x 500 MM chamber Combustion Furnace manufacturer