Web Analytics Made Easy - Statcounter
 +91 8100640898 (11 AM to 6 PM)    +91 9475747057
1200°C Sulfur Determination Furnace Chamber 620 × 620 × 890 MM / 62 × 62 × 89 CM / 24 × 24 × 35 INCH | Manufacturer India
This is a sample image
actual model may differ
Direct Manufacturer GST Invoice Pan-India Delivery
Temperature: 1200°C / 2192°F

1200 degree Celsius (°C) SULFUR DETERMINATION FURNACE CHAMBER SIZE 620 × 620 × 890 MM

View in:
4.6 (11 ratings)
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
Base Price (Excl. GST)
₹180,630.00
+ Packaging: ₹14,781.62 (optional for factory/self pickup)
+ GST (18%): ₹32,513.40
* Shipping calculated at checkout
Est. Total (incl. GST + packaging): ₹227,925.02
units
📫 Enquire
Product Specifications
CategoryMuffle Furnace
ModelSulfur Determination Furnace
Max Temperature1200°C (2192°F)
Working Temperature1100°C
Thermocouple TypeS (Platinum-10% Rhodium)
Thermocouple DetailsType S, Tolerance Class 2, 0 to +1450°C range, High purity alumina insulation, Platinum sheath, 6mm diameter
Heating ElementKanthal A1 (FeCrAl)
Element DetailsFeCrAl alloy with rare earth elements, Max temp: 1425°C, Superior cyclic performance
Chamber (MM)620 × 620 × 890
Outer Body (MM)1020.0 × 1220.0 × 1165.0
Chamber Volume342.1 Litres
Volume (cu.ft)54.6 ft³
Power Load30.600 kW
Power Supply440V, Three Phase
Gross Weight438 kg
Chamber ShapeSquare
Customise Your Order
Body Material
Body Paint Type
Temperature Controller
Safety Device

About This 1200°C Sulfur Determination Furnace 620 × 620 × 890 MM Chamber

This analytical furnace is used to determine the sulfur content in materials like coal, oil, and steel. Operating at high temperatures (around 1000°C), it combusts the sample in an oxygen-rich environment. The working principle involves burning the sample, converting all sulfur to sulfur dioxide (SO2), which is then measured by infrared detection or titration. Its purpose is critical for environmental compliance (monitoring fuel sulfur levels), metallurgical quality control (sulfur weakens steel), and in the petrochemical industry for feedstock analysis.

Trutherm manufactures 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 620 × 620 × 890 MM Chamber for buyers who search by exact machine type, chamber size and 1200°C temperature rating. This page is specific to the MM dimension version, so the chamber size is presented in the unit normally used in the buyer's drawing, tender or purchase request.

This configuration is suitable when the sample load must fit a 620 × 620 × 890 MM chamber with usable chamber volume of 342.1 litre, approximate power load of 30.600 kW, square chamber profile. It is commonly selected for laboratory, QC, metallurgical, ceramic, pharmaceutical and industrial heat-treatment work requiring stable heating and repeatable process conditions.

Equivalent chamber references: 620 × 620 × 890 MM, 62 × 62 × 89 CM and 24 × 24 × 35 INCH. Buyers searching for 1200 Degree Celsius Sulfur Determination Furnace 620 × 620 × 890 MM chamber; 1200°C Sulfur Determination Furnace 620 × 620 × 890 MM; 1200 Degree Celsius Sulfur Determination Furnace 62 × 62 × 89 CM chamber; 1200°C Sulfur Determination Furnace 62 × 62 × 89 CM; 1200 Degree Celsius Sulfur Determination Furnace 24 × 24 × 35 INCH chamber; 1200°C Sulfur Determination Furnace 24 × 24 × 35 INCH can verify the same physical chamber on this canonical product page before requesting price, GST invoice, packaging and delivery.

FAQs for 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 620 × 620 × 890 MM Chamber

What is 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 620 × 620 × 890 MM Chamber best suited for? It is best suited for controlled heating jobs where this exact 620 × 620 × 890 MM chamber size must fit the sample, crucible, tray or batch volume.
Can Trutherm supply 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 620 × 620 × 890 MM Chamber with custom controls? Yes. Controller type, safety devices, body material, power connection and documentation can be configured according to application and site requirements.
Is this chamber size available in CM and INCH also? Yes. The same chamber is listed as 620 × 620 × 890 MM, 62 × 62 × 89 CM and 24 × 24 × 35 INCH so searches and purchase documents using any common dimension unit match this product.
How is pricing decided for 1200 Degree Celsius (1200°C) Sulfur Determination Furnace 620 × 620 × 890 MM Chamber? Price depends on chamber size, temperature rating, insulation, heating element, controller, electrical load, packaging, GST and delivery requirements.

Related Furnace Pages

Sulfur Determination Furnace manufacturer 1200 Degree Celsius Sulfur Determination Furnace chamber sizes Sulfur Determination Furnace 890 × 620 × 620 MM chamber Sulfur Determination Furnace 620 × 890 × 620 MM chamber Sulfur Determination Furnace 700 × 700 × 700 MM chamber Sulfur Determination Furnace 625 × 625 × 880 MM chamber
Product Enquiry
Verify: 19 + 20 = ?

Products You May Be Interested In

Glass Fusing Furnace
Muffle Furnace
Glass Fusing Furnace
High-Temperature Heat Treatment Furnace
Muffle Furnace
High-Temperature Heat Treatment Furnace
Non-Ferrous Metal Furnace
Muffle Furnace
Non-Ferrous Metal Furnace
Dental Furnace
Muffle Furnace
Dental Furnace
Electric Ceramic Kiln
Muffle Furnace
Electric Ceramic Kiln
Ash Fusion Furnace
Muffle Furnace
Ash Fusion Furnace